JAVMA BOAS study recap: CO₂ laser vs cut-and-sew vs LigaSure (413 dogs)
Many veterinarians treat BOAS patients or collaborate with teams who do. One of the most common clinical questions is simple: when you perform a staphylectomy, do outcomes differ based on the technique and tool used?
A recent JAVMA retrospective review provides real numbers for that discussion. The study evaluated 413 canine BOAS staphylectomy cases (2012–2024) and compared short-term major complications across multiple techniques.
What techniques were compared
Cases were grouped by staphylectomy method, including:
- Cut-and-sew
- CO2 laser staphylectomy
- Bipolar vessel-sealing device (BVSD) using the LigaSure Precise handpiece (Medtronic)
(An additional group in the paper includes BVSD with suture apposition, but this recap focuses on the clearest day-to-day tool comparisons: CO2 laser vs cut-and-sew and CO2 laser vs BVSD.)
Group sizes were: cut-and-sew 94, CO2 laser 101, and BVSD 104.
What counted as a “major complication”
Major complications were defined as clinically meaningful postoperative events that required a significant escalation of care. Examples included aspiration pneumonia, temporary tracheostomy, persistent regurgitation, post-op respiratory crisis requiring reintubation or oxygen supplementation, or erratic recovery requiring sedation.
The key numbers (major complication rates)
Across the full cohort, major complications occurred in 15.5% of dogs.
By technique, reported major complication rates were:
- Cut-and-sew: 20.2% (19/94)
- CO2 laser: 12.9% (13/101)
- BVSD (LigaSure): 18.3% (19/104)
Putting the differences into plain language
CO2 laser vs cut-and-sew
- 12.9% vs 20.2% major complications
- 7.3 percentage points lower with the CO2 laser
- About 36% lower relative to cut-and-sew
CO2 laser vs BVSD (LigaSure)
- 12.9% vs 18.3% major complications
- 5.4 percentage points lower with the CO2 laser
- About 30% lower relative to BVSD
The authors also note in the discussion that, in this dataset, the CO2 laser was least likely to result in a short-term major postoperative complication.
One more result worth noting
In multivariable analysis, cut-and-sew had significantly higher odds of major complications compared with CO2 laser (OR 2.9, 95% CI 1.2–7.4).
Why ALSC members may want to read it
This paper is a useful reference for:
- Surgeon-to-surgeon discussion of technique selection in BOAS staphylectomy
- Communicating risk in a more structured way using a clear definition of “major complications”
- Reviewing how different tools may relate to early post-op outcomes in a large dataset